[email protected]·Specification-matched quotation within 24 hours About UsRequest a Quote

Home Backup Power Stations

Home backup power station product photo
3.6–5.4kWhLFP capacity
7,200Wparallel output
120V/30Aemergency EV output
-10°C / 85%cold-weather retention

Keep a refrigerator, well pump and sump pump running through any outage: the 3.6–5.4kWh LFP flagships run 7,200W when paralleled, charge an EV in an emergency, and hold 85% output at -10°C.

Product Images

Highlights

Parallel for the whole house

Two flagships in parallel = 7,200W — run fridge, well pump, lights and AC starter loads together.

Emergency EV charging

Plus variant outputs 120V/30A — level-1, get-home miles when the grid is down.

Cold-weather rated

85% output retention at -10°C on cold-weather models.

Expandable, not replaceable

Add expansion batteries or 2,400W solar input instead of buying a new unit.

Applications

Outage essentialsFridge, sump pump, CPAP, lights, router
Well-water homes3,600W surge headroom for pump start loads
EV ownersEmergency level-1 charging
Retail programsWill-it-run-my appliance math shelf cards

Full Specifications

ItemSpecificationEvidence
Flagship (Plus)3,686Wh LFP; 3,600W; parallel 7,200W; EV output 120V/30A; expansion-battery portT2 · Catalog
Mid flagships1,024–2,048Wh; 1,800–2,400W; -10°C at 85% outputT2 · Catalog
Outdoor model2,074Wh NCM; 3,600W; IP65; 22kg; 5× overloadT2 · Catalog
Solar inputUp to 2,400W on flagships (10–150Vdc MPPT)T2 · Catalog
UPS transfer≤25msT2 · Catalog
Runtime mathFridge 1–2+ days; CPAP many nights; well pump per LRA check (calculator in quotation pack)T3 · Field data

Evidence codes: T1 = factory specification sheet, T2 = product catalog, T3 = field/case data. Runtimes are engineering estimates by load.

Why source this through Benelabo

Four product lines — vehicles, energy storage, farm machinery and engines — from long-established Chongqing manufacturing bases, exported through one channel under one QC standard.

  • One mixed container — vehicles, batteries, machines and spares ship together; 220+ SKUs on one loading plan cuts freight and admin cost per line.
  • One QC & export standard — factory specification sheet and certification status attach to every quotation, answered within 24 hours.
  • Field-proven flagship tech — immersion-cooled storage in oilfield service since 2022 at 8.1% of diesel energy cost.
  • SKD / CKD routes — local-assembly programs ready where import policy requires them.

How to Choose

  • Load list first — refrigerators, sump pumps and CPAP have different surge profiles; size from the appliance list, not the marketing wattage.
  • Expandability — dual-unit parallel (7,200W class on the home backup line) doubles output without doubling SKUs.
  • Channel fit — retail shelves need NA/EU certification packs (UN38.3, ETL-UL, FCC, CE); ODM programs take the same platforms private-label.

Where this line sits

The home backup line sits at the household end — essential-load backup with parallel-ready architecture.

Portable & Home Backup Finder

LineClassDutyBest for
Portable Power Stations179Wh–5.4kWh LFPPortable power, two manufacturing linesRetail, dealer shelves, ODM
Home Backup StationsHome-class capacity, dual-unit 7,200WEssential-load home backupOutage-prone grid markets
ODM / OEM Programs179Wh–5.4kWh platformsPrivate-label power stationsBrands & importers

Compare the full range: Power Station ODM / OEM →

Application & Site Photos

Application photos, company floor and exhibition photos for this line are being prepared — tell us your market and we share the matching site set with your quotation.

How It Performs in the Field

The pain points buyers raise most — and what the line does about them:

  • Outage-prone grids make fuel generators costly to run — home backup stations cut noise and running cost for essential loads.
  • Portable-class simplicity with home-class capacity: no installation crew required for basic backup setups.

Trade & Ordering Notes

  • Mixed loading is standard — mixed models and mixed categories in one container are accepted; per-model MOQ is confirmed in the quotation.
  • 24-hour quotations — specification-matched replies on business days, with the factory specification sheet and certification status attached.
  • Terms confirmed in writing — payment, production lead time and warranty are fixed per model and destination in the quotation, with no post-signing surcharges.
  • Export-ready documentation — HS classification and the export document set are issued per model; SKD/CKD component programs are available where market policy requires local assembly.

How We Work with You

1 · Send RFQSpecification-matched reply within 24 hours on business days.
2 · Confirm specificationEngineered projects receive a configuration document within 48 hours.
3 · Production & QCEvery quotation carries the factory specification sheet and certification status.
4 · Shipment & deliveryExport documentation set with HS classification, issued per model.

FAQ

Will it run a refrigerator? How long?

A typical fridge cycles well within 3.7kWh — estimate 1–2+ days per full charge, load-dependent.

Can it start a well pump?

Yes — 3,600W+ inverters have surge headroom for pump start loads; check your pump’s LRA before ordering.

What happens during a multi-day outage?

Add expansion batteries or solar input to extend runtime indefinitely.

Can it charge an EV?

The Plus variant provides 120V/30A emergency EV charging — level 1, miles-per-hour class.

Get wholesale pricing for home backup units.

Specification-matched quotation with certification status, replied within 24 hours on business days.

Request a Quote Why Benelabo